{"product_id":"trident-p2-surgical-respirator-level-3-hospital-grade-regular-size-1-box20masks","title":"Trident P2 Surgical Respirator  Level 3 Hospital Grade  Regular Size (1 Box\/20masks)","description":"\u003cp\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003ePRODUCT NAME - ON SPECIAL\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cspan style=\"font-size: 1.4em;\" data-mce-fragment=\"1\"\u003e\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eTrident P2 Level 3 Surgical Disposable Respirator\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eEach box contains 20 individually packaged masks.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eView product information sheet\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e \u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSTANDARDS ACHIEVED\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"MMM--pdpList SNAPS--bullets\" data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eP2 certified\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"tm_textblock-css-head-22 section-block pt-5 pb-30 Product-intro\" data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"row\" data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"column_inner-css-head-21 column background-cover width-12 v-align-middle left left-on-mobile\" data-mce-fragment=\"1\"\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003eARTG 344154\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eHospital Grade\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eAS 4381: 2015 Level 3, 160 mmHg (ID No. BMP 737354)\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"row_inner-css-head-10 section-block replicable-content no-padding certification\" data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"row flex\" data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"column_inner-css-head-13 column background-cover width-10 v-align-middle left left-on-mobile\" data-mce-fragment=\"1\"\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003eAS\/NZS 1716: 2012 (ID No. BMP 732382)\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eKEY FEATURES\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eAdvanced multilayer technology providing protection against mechanically and thermally generated particulates including: fluids, dusts, mists, fumes and smoke\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eThree panel design provides structural integrity, form fit seal and optimal comfort. All three mask panels and seams have been independently tested and certified to AS 4381:2015 Level 3 – ISO 22609\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eBacterial Filtration Efficiency (BFE) \u0026gt;99%\u003cbr data-mce-fragment=\"1\"\u003e\n\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eFluid protection level 3, 160 mmHg\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eProprietary adjustable foam nose pad to ensure consistent optimum facial seal and reduce fogging of eyewear\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eVersatile unisex fit suitable for a range of facial shapes and sizes. Effective for many “hard to fit” individuals\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eSpecialised TRIDENT\u003csup data-mce-fragment=\"1\"\u003e®\u003c\/sup\u003e respirator seal attains unrivalled PortaCount\u003csup data-mce-fragment=\"1\"\u003e®\u003c\/sup\u003e fit testing results\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eLow breathing resistance, maximizing wearer comfort, durability and life of product\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eDesigned to be used in conjunction with other mandatory personal protective equipment\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eEach mask is individually batch numbered and packaged for the ultimate in traceability, portability and hygiene\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"tm-feature-section-css-head-57 section-block no-padding section-block  feature-2 right\" data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"row flex\" data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"column width-5 offset-1\" data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"feature-content tmh-perspective\" data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"feature-content-inner left horizon\" data-animate-in=\"preset:fadeIn;duration:1000ms;delay:0ms;\" data-threshold=\"0.5\" data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eLatex free to avoid the risk of developing allergies with repeat exposure\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-mce-fragment=\"1\"\u003e \u003c\/p\u003e\n\u003cdiv class=\"m-footer\" data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"m-footer_container\" data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\u003c\/ul\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eHOW TO APPLY – DONNING\u003c\/strong\u003e\u003c\/p\u003e\n\u003col data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003ePosition the respirator in the palm of your hand with the nose strip at your fingertips, ensuring both head straps are untwisted over the back of your hand.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eOpen both the top and bottom panels of the mask and make a bend in the foam nose seal. Place the lower panel under the chin and the upper panel with the foam nose seal over the nose bridge and underneath the eyes.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eHolding the respirator with one hand, position the top untwisted head strap to the crown of the head.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eDraw the lower untwisted head strap up and over the face to below the ears and back of the neck. \u003cstrong data-mce-fragment=\"1\"\u003eDO NOT CRISS CROSS HEADSTRAPS.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eWith both hands, mould the foam nose seal at the top of the mask to the nose bridge and cheeks ensuring a secure fit and seal.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003ePerform a fit check (see fit check list below). Cover the front of the respirator with both hands. Inhale and exhale sharply.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp data-mce-fragment=\"1\"\u003e \u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eHOW TO APPLY – DOFFING\u003c\/strong\u003e\u003c\/p\u003e\n\u003col data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eThe respirator may be contaminated. Touch only the head straps when removing.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003ePull the bottom strap over the top of the head.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003ePull the top strap over the top of the head.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eDispose of respirator into the appropriate waste receptacle in accordance with site infection control and prevention policies.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eWash and sanitise your hands thoroughly.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp data-mce-fragment=\"1\"\u003e \u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eFIT CHECK LIST\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"column_inner-css-head-88 column background-cover width-6 v-align-middle left left-on-mobile\" data-mce-fragment=\"1\"\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eIf air leaks at the nose or cheek areas adjust the foam nose seal until a seal is achieved.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eIf air leaks around the edge of the respirator adjust the head straps and reposition the mask until a seal is achieved.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eA successful fit check is when there is no air leakage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column_inner-css-head-90 column background-cover width-6 v-align-middle left left-on-mobile\" data-mce-fragment=\"1\"\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eAlways fit check before entering the work area.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eIf a successful fit check cannot be achieved, remove and refit the respirator.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eIf you still cannot obtain a successful fit check, do not enter the work area.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-mce-fragment=\"1\"\u003e \u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eNOTE:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e To achieve an optimum facial seal, the wearer should be clean-shaven. It is recommended the wearer be fit tested prior to use in accordance with AS\/NZS 1715: 2009 and\/or onsite requirements. Training on the safe use and limitations of the disposable face mask must be performed in accordance with AS\/NZS 1715: 2009 section 2.4.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e \u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eFor bulk orders over 500 masks please contact Oz Medical 0431 000 991\u003c\/p\u003e","brand":"Trident","offers":[{"title":"Default Title","offer_id":47572514832438,"sku":"dax1788030708298","price":36.53,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0669\/5590\/3030\/files\/trident-p2-surgical-respirator-level-3-hospital-grade-regular-size-1-box20masks_1.jpg?v=1788030713","url":"https:\/\/www.keystonebasket.shop\/products\/trident-p2-surgical-respirator-level-3-hospital-grade-regular-size-1-box20masks","provider":"My Store","version":"1.0","type":"link"}